Electrical Warning Signs: Danger of Death, Voltage and Isolation Labels
Electricity cannot be seen, heard or smelled, so signs are often the only warning people get that a hazard is there. Electrical warning signs and labels are needed on switchrooms, distribution boards, plant, overhead lines, solar installations and anywhere live parts could be reached. This guide explains the main signs and labels and where they belong.
The law
- The Electricity at Work Regulations 1989 require electrical systems to be constructed, maintained and worked on so as to prevent danger. Warning signs are one way of controlling the risk from equipment and areas that cannot be made completely safe.
- The Health and Safety (Safety Signs and Signals) Regulations 1996 require safety signs where a significant risk remains after other controls. See our guide to the safety signs regulations.
- BS 7671, the IET Wiring Regulations, sets out labels and notices that should be fitted to electrical installations, such as periodic inspection notices and warnings about dual supplies.
The electricity warning symbol
The standard electrical warning sign is a yellow triangle with a black border and a black lightning bolt. In BS EN ISO 7010 it is coded W012, warning: electricity. It is often combined with text such as "Danger: electricity" or "Danger of death". See our electricity warning sign.
Common electrical signs
Danger of death. Used where contact with live parts could be fatal, for example on high voltage equipment, substations, transformer enclosures and overhead line supports. These signs often use the lightning bolt symbol with bold text.
Voltage warning signs. Signs stating the voltage present, such as "Danger 415 volts" or "Danger 400 volts", are used on switchgear and distribution boards where the voltage is higher than people would expect. BS 7671 requires a warning where a voltage exceeding 230 volts exists and would not normally be expected.
Switch room and plant room signs. "Danger: switch room" or "Authorised personnel only" signs on doors to rooms containing electrical equipment, combined with prohibition signs to keep unauthorised people out.
Isolation signs. Labels identifying isolators, emergency switches and main switches, so people can find and operate them quickly. "Emergency stop" and "Main isolator" labels are common.
Do not switch on: men at work. Temporary signs used during safe isolation, attached to locked off isolators while work is carried out. They work with a lock off system so that equipment cannot be re energised by mistake.
Overhead power lines. Warning signs and goal posts at farms, construction sites and car parks where vehicles or equipment could touch overhead lines. See our guide to construction site signs.
Do not extinguish with water. A prohibition sign used near electrical equipment and switchrooms, where water would be dangerous. See our do not extinguish with water sign.
BS 7671 labels on installations
Electricians fitting or testing installations should also fit labels required by BS 7671. Common ones include:
- Periodic inspection notice at the origin of the installation, showing the date of the last inspection and when the next is due.
- RCD test notice, telling users to test residual current devices regularly by pressing the test button.
- Safety electrical connection: do not remove, on main earthing and bonding connections.
- Warning of dual supply, where the installation is fed from more than one source, such as solar panels or a generator.
- Circuit charts and schedules at distribution boards.
- Warning notices for mixed wiring colours, where an installation has both old and new cable colours.
Solar PV and battery storage
Solar panel and battery installations bring extra hazards, because parts of the system can remain live even when the mains supply is switched off. Typical labels include:
- Dual supply warning labels at the consumer unit, the meter position and the point of isolation, warning that there is a second source of supply.
- PV isolator labels on DC and AC isolators.
- Warnings that DC cables and components may remain live during daylight.
- Battery storage warning labels identifying the battery and its hazards.
These labels protect electricians, firefighters and anyone working on the system. Firefighters in particular need to know a building has solar or battery storage, so a label near the main entrance or fire alarm panel is good practice.
Electric vehicle chargepoints
Workplace and public EV chargepoints should be clearly marked, with emergency isolation points labelled. Trip hazards from cables and vehicle movements should also be considered in the risk assessment.
Where to put electrical signs
- On the doors of switchrooms, plant rooms and substations.
- On the covers of distribution boards, control panels and junction boxes.
- On fences and enclosures around transformers and high voltage equipment.
- On isolators and emergency switches.
- Near overhead lines, at points where vehicles approach.
- At solar PV and battery equipment, as above.
Signs should be fixed securely, easy to read, and placed where people will see them before they reach the hazard.
Choosing the right material
- Self adhesive vinyl works well on distribution boards and panels.
- Rigid plastic or aluminium composite for doors, fences and outdoor locations.
- Engraved or durable labels for permanent identification of isolators and circuits.
Avoid metal signs fixed directly onto live equipment enclosures unless suitable for the purpose.
Browse our electrical safety signs range, or the electrical safety pack for a ready set.
Keeping signs effective
- Replace faded or damaged signs, especially outdoors.
- Update voltage and isolation labels after changes to the installation.
- Do not let signs be painted over or covered by equipment.
- Explain signs and isolation procedures to staff and contractors.
Safe isolation and lock off
Signs are not a substitute for safe working. Before working on electrical equipment, electricians follow a safe isolation procedure: identify the circuit, isolate it, lock off the isolator with a personal lock, attach a warning tag, prove the circuit is dead with an approved voltage indicator, and check the indicator works before and after. The warning tag, often stating "Danger: do not switch on, men at work", tells others why the equipment is locked off and who to contact.
Many workplaces keep lock off kits and warning tags near the main distribution boards. Make sure everyone who might switch equipment back on knows never to remove someone else's lock or tag.
Electrical rooms and housekeeping
Switchrooms and plant rooms should be kept locked, clear of stored materials, and free of combustible items. They are a common place for rubbish and spare stock to build up, which creates a fire risk and blocks access to equipment. A "Switch room: keep clear" or "No storage" sign on the door helps, along with regular checks.
Portable equipment
Warning signs mainly apply to fixed installations, but portable electrical equipment needs care too. Users should check leads and plugs before use, and equipment should be inspected and tested at a frequency based on risk. Labels showing the date of the last check are common, although not a legal requirement.
Key points
- The lightning bolt in a yellow triangle is the standard electrical warning.
- Use danger of death and voltage signs where live parts could be fatal or the voltage is unexpected.
- Fit BS 7671 labels, including periodic inspection, RCD test and dual supply warnings.
- Label solar PV and battery systems clearly for electricians and firefighters.
- Keep switchrooms locked, clear and signed.
Quick answers
What does the yellow triangle with a lightning bolt mean? Warning: electricity. It is ISO 7010 sign W012.
Are electrical warning signs a legal requirement? Where a significant electrical risk remains after other controls, safety signs law requires them. BS 7671 also specifies labels for installations.
What labels does a solar PV system need? Dual supply warnings at the consumer unit, meter and isolation point, labelled isolators, and warnings that DC parts may remain live.
Where should a danger of death sign go? On equipment, enclosures and areas where contact with live parts could be fatal, such as substations, high voltage equipment and switchrooms.
Common questions
What does a yellow triangle with a lightning bolt mean?
It is the warning sign for electricity, ISO 7010 W012, warning of electrical hazards such as live parts.
Do I need a danger of death sign?
Where contact with live parts could be fatal, such as on high voltage equipment, substations and some switchrooms, a danger of death warning is standard practice and part of controlling the risk.
What labels are needed for solar panels?
Dual supply warning labels at the consumer unit, meter and point of isolation, labelled DC and AC isolators, and warnings that DC parts may remain live in daylight.
What is an RCD test notice?
A label required by BS 7671 telling users to test residual current devices regularly by pressing the test button.
More guides
- CCTV Signs: UK Legal Requirements and What to Include
- No Smoking Signs: The Law in England, Scotland, Wales and Northern Ireland
- Fire Exit Signs: UK Requirements, Arrows and Placement
- Fire Door Signs: Which Ones You Need and Where
- Fire Action Notices: What to Include and Where to Put Them
- First Aid Signs: UK Requirements and Where to Put Them
- COSHH Hazard Symbols: The Nine Pictograms and What They Mean
- Health and Safety (Safety Signs and Signals) Regulations 1996 Explained
- Fire Extinguisher Signs and Colours: Types, Labels and Placement
- Construction Site Signage: What You Need on Site
- Fire Safety Signs: A Plain Guide to UK Requirements
- Photoluminescent Safety Signs: When You Need Glow in the Dark
- What Size Safety Sign Do I Need?
- Safety Sign Symbols and What They Mean
- Safety Sign Colours and Meanings: The Five Types Explained
- Safety Sign Materials Compared: Vinyl, Rigid, Foamex, Aluminium, Glow and Reflective