Fire Door Signs: Which Ones You Need and Where
Fire doors only work if they are closed when a fire starts. They hold back fire and smoke for a set time, protecting escape routes and giving people time to get out. The signs on them are there to make sure people keep them shut, or locked, or clear. This guide explains which fire door sign goes where.
Why fire door signs matter
A fire door wedged open, or a door to a riser cupboard left unlocked and filled with rubbish, can let fire and smoke spread rapidly through a building. Signs remind everyone who uses the building how each fire door should be treated. Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person must keep fire safety measures, including fire doors, in good working order. Signage is part of that, and your fire risk assessment should identify which doors need which signs.
The guidance on fire door signs is set out in Approved Document B to the Building Regulations and BS 5499. Fire door signs are mandatory signs, with white text and symbols on a blue background.
The three main fire door signs
Fire door keep shut. Used on self closing fire doors, normally on both sides of the door. It tells people the door must not be wedged or propped open. See our fire door keep shut sign.
Fire door keep locked. Used on fire doors to cupboards, stores and service ducts that are kept locked rather than self closing, usually on the outside of the door only. See our fire door keep locked sign.
Automatic fire door keep clear. Used on fire doors held open by an automatic release device, such as an electromagnetic hold open linked to the fire alarm. The door closes automatically when the alarm sounds, so it must not be obstructed. Signs go on both sides. See our automatic fire door keep clear sign.
Doors that do not usually need signs
Guidance generally does not require fire door signs on:
- doors to and within individual flats and houses
- bedroom doors in hotels and similar accommodation
- lift entrance doors
Your fire risk assessment may still decide signs are helpful on some of these, but for most buildings the focus is on doors in common areas, corridors, stairways and service areas.
Where to put the signs
- At eye level, typically around 1.5 metres from the floor, and centred on the door or on the opening side, so they are easy to read.
- On both faces of self closing and automatic doors.
- On the outside face of fire doors that are kept locked.
- On the door itself, not the frame or wall beside it.
Use self adhesive vinyl or rigid plastic signs fixed securely. Do not drill large holes in fire doors to fix signs, as that can affect fire performance. Adhesive or small screws as recommended by the door manufacturer are best.
Fire doors in blocks of flats
The Fire Safety (England) Regulations 2022 introduced extra duties for responsible persons in residential buildings with two or more sets of domestic premises:
- In buildings over 11 metres high, fire doors in communal areas must be checked at least every three months, and flat entrance doors at least every twelve months, on a best endeavours basis.
- All such buildings must give residents fire safety instructions and information about the importance of fire doors.
- In buildings over 18 metres, wayfinding signage for firefighters is required, showing floor numbers and flat numbers in the stairs and lift lobbies.
Communal fire doors in these buildings should carry the right fire door signs, and residents should be told why the doors must be kept shut.
Fire door checks
Signs are only part of the picture. Regular checks should look for:
- doors that are wedged or propped open
- self closers that do not close the door fully into its frame
- gaps around the door larger than the manufacturer allows, typically around 2 to 4 millimetres
- damaged or missing intumescent strips and smoke seals
- hinges, locks and handles that are loose or damaged
- missing or damaged signs
Record each check and fix any faults quickly.
Common problems
- Wedging doors open for convenience. If a door is regularly propped open, consider an automatic hold open device linked to the fire alarm, and change the sign to Automatic fire door keep clear.
- Signs on one side only of self closing doors.
- Wrong sign on the wrong door, such as Keep locked on a door that is meant to be self closing.
- Old, faded or painted over signs.
- Signs fixed in a way that damages the door.
Choosing your fire door signs
- Material: self adhesive vinyl works well on smooth painted doors. Rigid plastic is more durable in busy corridors.
- Size: fire door signs are usually small, but they must be clearly readable. Common sizes are around 100 by 100 millimetres or 150 by 200 millimetres.
- Photoluminescent versions: useful on escape routes where lighting may fail.
Browse our full range of fire door signs.
Related signs
Fire doors often sit on escape routes, so check that your fire exit signs and fire action notices are in place too, and read our overview of fire safety signs.
Hotels and houses in multiple occupation
In hotels, guest houses and houses in multiple occupation, fire doors on corridors and stairways are critical, because people are asleep and may be unfamiliar with the building. Fire door keep shut signs on both sides of corridor and stair doors are standard, and doors to cupboards and service risers in common areas should be kept locked and signed. Bedroom doors are usually self closing fire doors but often do not carry keep shut signs. Follow your fire risk assessment and the guidance for your type of premises.
Wedges and door stops
Wedging open a fire door is one of the most common fire safety failings found by inspectors. If people need a door open for ventilation, accessibility or convenience, the answer is an approved hold open device or a free swing door closer that releases when the fire alarm sounds. Change the sign to Automatic fire door keep clear once the device is fitted, and test the release with the weekly fire alarm test.
Glazed fire doors
Many fire doors have glass panels, which must be fire rated glass. Fix signs to the solid part of the door where possible. If a sign must go on glass, use a self adhesive vinyl sign that does not affect the glass or its fixings, and never drill into fire glass.
Fire doors and signs checklist
- Every self closing fire door: Fire door keep shut on both sides.
- Every locked fire door to a cupboard, store or riser: Fire door keep locked on the outside.
- Every fire door with a hold open device: Automatic fire door keep clear on both sides.
- Signs at eye level, clean, readable and undamaged.
- Doors closing fully, with no wedges or obstructions.
- Checks recorded in your fire safety log book.
Key points
- Fire door keep shut: both sides of self closing fire doors.
- Fire door keep locked: outside of locked cupboard and riser doors.
- Automatic fire door keep clear: both sides of doors on hold open devices.
- Signs are blue mandatory signs, fixed at eye level without damaging the door.
- Check doors and signs regularly and record the checks.
Quick answers
Is a fire door keep shut sign a legal requirement? Fire safety law requires fire doors to be maintained and escape routes protected. Guidance in Approved Document B and BS 5499 recommends Fire door keep shut signs on both sides of self closing fire doors, and fire risk assessments will normally require them.
Do fire door signs go on both sides? Keep shut and Automatic fire door keep clear signs go on both sides. Keep locked signs usually go on the outside only.
What colour are fire door signs? Blue background with white text, because they are mandatory signs.
Do flat front doors need fire door signs? Usually not, though the doors themselves must be fire doors in many blocks.
Common questions
Do fire doors legally need signs?
Fire safety law requires fire doors to be maintained and effective. Building guidance recommends Fire door keep shut signs on both sides of self closing fire doors, and fire risk assessments normally require them.
Which side of the door does a fire door keep shut sign go on?
Both sides of self closing fire doors. Fire door keep locked signs usually go on the outside face only.
What is an automatic fire door keep clear sign for?
For fire doors held open by an automatic device that releases when the fire alarm sounds. The sign warns people not to block the door so it can close.
Do flat entrance doors need fire door signs?
Usually not. Guidance generally exempts doors to and within flats, hotel bedroom doors and lift doors.
More guides
- CCTV Signs: UK Legal Requirements and What to Include
- No Smoking Signs: The Law in England, Scotland, Wales and Northern Ireland
- Fire Exit Signs: UK Requirements, Arrows and Placement
- Fire Action Notices: What to Include and Where to Put Them
- First Aid Signs: UK Requirements and Where to Put Them
- COSHH Hazard Symbols: The Nine Pictograms and What They Mean
- Health and Safety (Safety Signs and Signals) Regulations 1996 Explained
- Electrical Warning Signs: Danger of Death, Voltage and Isolation Labels
- Fire Extinguisher Signs and Colours: Types, Labels and Placement
- Construction Site Signage: What You Need on Site
- Fire Safety Signs: A Plain Guide to UK Requirements
- Photoluminescent Safety Signs: When You Need Glow in the Dark
- What Size Safety Sign Do I Need?
- Safety Sign Symbols and What They Mean
- Safety Sign Colours and Meanings: The Five Types Explained
- Safety Sign Materials Compared: Vinyl, Rigid, Foamex, Aluminium, Glow and Reflective